Operation; Decommissioning - Abicor Binzel FEC Manual De Instrucciones

Extractor de humos
Ocultar thumbs Ver también para FEC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FEC

7 Operation

WARNING
Hazard due to overheating
Increased wear to the electric motor due to overheating.
• A cool-down period of at least 5 minutes must be observed for every 30 minutes of operating time.
• This value may change depending on the ambient temperature of max. 25°C.
CAUTION
Risk of injury
Damage from improper use
• Be sure that the housing does not make contact if you pass over edging, because damage to the housing could occur.
• Do not point the suction hose at a person and do not use the product to clean clothing.
• Do not suction up flammable substances or liquids.
• Provide sufficient ventilation during operation of the fume extraction system.
 6.1 Transport and installation on page EN-11
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.

8 Decommissioning

1 Switch off the fume extraction system on the control panel with the "0 / Error" button.
2 Disconnect the fume extraction system from the power supply.
3 If necessary, disconnect the fume extraction system from the compressed air supply and ground cable.
NOTICE
• If the motor protective switch (1) is triggered, check for the cause.Reset it once the cause has been remedied.
 10 Troubleshooting on page EN-24
1
Motor protective switch
Fig. 9
Motor protective switch
BAL.0533.0 • 2019-11-15
1
7 Operation
EN - 15

Publicidad

Tabla de contenido
loading

Tabla de contenido