9 Maintenance and cleaning

9.4 Changing the filter

1 Switch off the power to the fume extraction system.
2 Dedust the filter cartridge before changing the filter and empty the filter housing.
 9.2 Filter dedusting on page EN-18 and 9.3 Emptying the filter housing on page EN-19
CAUTION
• Check and wear your personal protective equipment.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
• Personal protective equipment must be worn when in the vicinity of the dust collecting bag as it is being filled with the
separated dust.
NOTICE
• The filter must be changed if, after multiple dedustings, the "Dirty" LED is still illuminated and no other error
has occurred.
9.4.1 Replace the protective underlay
1
1
Filter housing
Fig. 12
Replace protective underlay
1 After the system has been dedusted, disconnect the FEC from the compressed air connection.
2 Unlock (3) the filter housing (1).
3 Tip the filter housing (1) forward.
4 Place the protective underlay (4) (in the package with the new filter cartridge) on the extraction system.
EN - 20
2
2
Housing
3
3
4
Latch
4
Protective underlay
BAL.0533.0 • 2019-11-15