SUN P N
1.5 Operating instructions
Once the burner is installed and correctly adjusted, its operation is fully automatic without requiring any control by the
user. In case of anomalies or no fuel, the burner stops and shuts down. To avoid irregular burner operation it is advisable
to top-up the fuel before it finishes.
Make sure the room where the burner is installed is free of flammable materials or objects, corrosive gases and volatile
substances, and that it is not dusty. In fact, dust drawn by the fan sticks to the blades and reduces the air flow or ob-
structs the flame stability disk thereby affecting its efficiency.
B
Do not allow unskilled persons or children to tamper with the burner.
37
EN
cod. 3541F710 - Rev. 00 - 05/2017