After each change in settings, the power supply must be turned off for at least 30 seconds.
On/Off switch 3: this allows the impedance of the cable to be adjusted and is a great help in case of poor image
quality. To be set to ON or OFF depending on the quality of the video on the screen.
6. CONNECTING OPTIONAL EQUIPMENT
a. Additional MN IRON 2 monitor(s)
• The additional monitor is connected to the previous monitor using 2 wires.
• Installing this monitor forces you to modify the ID setting: HOUSE = 0 ROOM = 2 for an additional unit or
HOUSE = 1 ROOM = 1 for a second home (see wiring diagrams figs. 7-8-9)
• Press the
key, then select ID using the cursor,
address of your monitor by pressing the
menu with
.
• With this second monitor, you can choose the bell sound.
• This monitor does not have an SD slot or a multi-media menu.
b. Additional PL IRON 2 outdoor station
• The additional outdoor station is connected to the previous outdoor station using 2 wires.
• Installing this outdoor station forces you to modify the position of the micro-switches (see wiring diagram fig.
7-8-9 and chapter 5e)
0 1 1 1
ON
OFF
1 2 3 4
After each change in settings, the power supply must be turned off for at least 30 seconds
c. Activation of the dual-family mode
See the wiring diagram (figs 8 and 9)
- Modify the position of the micro-switches on the outdoor station (switch 4 to off) and, on the monitors, confirm
the ID settings according to your installation. (chap 6a)
The power supply must be turned off for at least 30 seconds
Note: The power supply must be turned off for at least 30 seconds whenever the product is not working properly and
in particular after:
- Adding a monitor
- Modifying the wiring
- Modifying the position of the micro-switches at the back of the monitor and outdoor station.
- Disconnect from the 230 V~ power source after a storm or repair work
SAFETY INSTRUCTIONS
The transformer must be installed on the DIN rail of a modular panel. It is understood that the terminal
covers must be re-installed; in addition the connection must be made on an electrical installation compliant
with standard NFC 15-100, in France, and ONCE THE WIRING HAS BEEN COMPLETED.
It is essential to ensure that the poles are correctly matched when connecting the power supply.
GB5
switch 1 and 2: outdoor station address
switch 3: impedance to be set depending on the quality of the video on the screen
switch 4: ON for 1 family, OFF for 2 families.
CFI EXTEL IRON 2 - V1 - 09/2013
, validate by pressing the
and
keys, validate your settings by pressing
key. You can set the
, exit the