ECOTRONIC tech
"in" - information Menu
The controller can display the following information:
t01
S1: Upper hot water tank PT1000 sensor (°C)
Only with SYSTEM 2 or SYSTEM 3
t02
S2: Hot water tank NTC sensor (°C)
t03
S3: Solar collector PT1000 sensor (°C)
t04
S4: Solar collector return NTC sensor (°C)
Only with SYSTEM 1 or SYSTEM 3
F05
Solar circuit flow (Lt_min)
Only with flow meter connected and activated
P06
Actual modulating circulating pump speed
(40%=Speed 1¸ 100%=Speed 5)
Press the Up/Down buttons to scroll the list of information. To display the value just press the Enter button at the
parameter. In case of damaged sensor, the controller will display dashes.
To return to the list of information just press the Enter button.
To return to the Service Menu just press the Info button. To exit the controller Service Menu press the Info button
for 10 seconds or exiting will be automatic after 15 minutes.
"Hi" - History Menu
The microprocessor is able to store the total hours with controller powered (Ht), the last 10 faults and other
information; Historical data H1 represents the most recent error that occurred; Historical data H10 represents
the least recent fault that occurred.
Ht
No. hours ECOTRONIC Tech operation (Supply)
H01
Fault code
H02
Fault code
H03
Fault code
H04
Fault code
H05
Fault code
H06
Fault code
H07
Fault code
H08
Fault code
H09
Fault code
H10
Fault code
H11
No. hours Solar circulating pump operation
H12
No. hours AUX1 output relay operation
H13
No. hours AUX2 output relay operation
H14
No. hours FREE CONTACT output relay operation
H15
Max. temp. S1: Upper hot water tank PT1000 sensor (°C)
Only with System 2 or System 3
H16
Max. temp. S2: Hot water tank NTC sensor (°C)
H17
Max. temp. S3: Solar collector PT1000 sensor (°C)
H18
Max. temp. S4: Solar collector return NTC sensor (°C)
Only with System 2 or System 3
H19
No. liters, solar circuit (liters)
Only with flow meter connected and activated
H20
Circulating pump average speed (%)
Cumulative calculation carried out only if circulating pump is running
BIL
Thermal quantity balance (KWh)
Cumulative calculation carried out only if circulating pump is running
150
cod. 3540V011 - 03/2017 (Rev. 00)
EN
between 01 and 180°C
between 01 and 125°C
between 01 and 180°C
between 01 and 125°C
00-99 Lt_min
0-100%
between 0 and 9999 hours
between 0 and 9999 hours
between 0 and 9999 hours
between 0 and 9999 hours
between 0 and 9999 hours
between 01 and 180°C
between 01 and 125°C
between 01 and 180°C
between 01 and 125°C
between 0 and 9999 liters
0-100%
between 0 and 9999 kWh