Boost Surface Pumps; Placement And Foundation; Pump Motor Wiring - Lorentz PS2-150 Manual De Instalación Y Operación

Ocultar thumbs Ver también para PS2-150:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

52
Pump Installation

8.6 Boost Surface Pumps

8.6.1 Placement and Foundation

WARNING – PS2 Boost pumps must not be
submerged in or exposed to other sources
of water, e.g. rain.
Operating noises – Make sure, by applying appropriate
measures, that the environment will not be impaired by any
sound produced by the pump.
Space – During installation, make sure that there is enough
space available to permit subsequent disassembly of the
motor unit.
WARNING – The pump might heat up in
operation. It must be installed on a non
flammable surface.
Connecting the pump to the foundation – Fastening
the pump to the foundation should be done exclusively by
using bolts, threads or dowels in order to avoid blocking the
removal of the motor unit.
CAUTION – Inlet- and outlet-pipes must
be attached to the pump free of tension.
Figure 19: LORENTZ boost pump

8.6.2 Pump Motor Wiring

L1 – L2 – L3 – ECDRIVE requires four-conductor (four-wire)
cable between the controller and the motor. The three wires
L1, L2 and L3 carry power. The fourth wire carries ground. To
reverse direction of rotation reverse any two phases.
CAUTION – No disconnect switches must
be installed between motor and pump
controller. Connecting the motor wire to
the switched-on controller can cause
damage. Such damage is excluded from
the warranty.
CAUTION – starting the boost pump
without setting the controller to boost
mode will damage the pump. Such damage
is excluded from the warranty.

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ps2-200Ps2-600Ps2-1800Ps2-4000

Tabla de contenido