4.2 Interchangeable nose piece
EN
The interchangeable nose piece holds and guides the nails when the tool is actuated. It is possible
to take out the nose piece for the clearing of jammed nails or to exchange the nose piece for
extended applications. To remove the nose piece, the magazine has to be removed first. How to
remove the magazine see chapter 4.5. Then you can change the nose piece by pulling it out.
4.3 Switch for depth adjustment
The switch for depth adjustment can be used to reduce the depth and choose how to set the nails –
flush or fully embedded. To adjust turn it to the right or left.
Standard driving depth
4.4 Removable stand
The removable stand makes it easier to hold the tool perpendic-
ular to the working surface to enhance better setting results. To
be able to work on uneven surfaces or in narrow edges/corners it
is possible to remove the stand. To remove the stand, release the
engaging mechanism by pulling lightly downwards and rotate the
support leg upwards until it can be withdrawn.
4.5 Magazine
The tool is equipped with a quick release system, that enables a
quick and easy clearance of jammed nails and a quickly change
of the interchangeable nose piece. To be able to remove the
magazine the easy nail push button has to be pulled back and be
engaged in the lock position. Pull the red quick release button
while moving the magazine towards the interchangeable nose
piece to remove the magazine from the tool. Then you are able to
pull out the nose piece.
32
Reduced driving depth