The arrester loop (fall arrest attachment element in the abdominal belt) may only be used in
conjunction with a guided type fall arrester. It must always be aligned in the centre of the abdominal
belt.
When using the full body harness with arrester loops, the necessity for an additional back support for
ergonomic reasons must be checked by a hanging test in the guided type fall arrester. Always check
for correct sitting of the full body harness and that the arrester loops are in the middle of the back!
When using the full body harness as a sit harness the front breast fall arrest attachment elements are
used as attachment elements.
To improve sitting comfort we recommend the use of the Adapter SP 1 or SP 2.
Before the first use as a sit harness familiarize yourself with the function. As a test, close to the
ground, sit in the harness and carry out a hanging test. Sitting in the harness should not normally cause
any discomfort, otherwise check the harness adjustment. Before and during use, it should be
considered how any potentially necessary rescue measures can be safely, quickly and effectively
carried out.
Attention:
When working in the sit harness, the protection against a fall from height must
always be effected by an additional fall arrest attachment element on the full body
harness.
The full body harness should only be used by fully trained and/or otherwise competent personnel, or
the user should be under the direct supervision of such a person. The safety harness may only be used
with the specified use conditions and for the specified intended use. Health related restrictions such as
heart or circulatory problems, regularly taking medicines, etc. can compromise the user's safety when
working aloft. There must be a rescue plan on hand in which all emergencies that can occur during
work are taken into account. The full body harness should be the personal property of the user. The
maximum rated load of the user is 140 kg. Protect the full body harness against sharp-edged objects,
welding sparks and other destructive or damaging hazards. The full body harness is temperature
resistant up to 60°C. If the full body harness is resold in another country, the reseller must make
available instructions for use, servicing, regular checking and maintenance in the language of the other
country.
3. Meaning of the Marking
A
MKA20 TriFit / MKA20 DuoFit / MKA20 EasyFit
MKA20 KlickFit / MKA20 E KlickFit / MKA20 E KlickFit Öse
EN 361 / EN358 / EN813
Mittelmann
0158
Year of Manufacturer: XXXX
Factory No.: xx – xxxxxx
Nominal load: 140 kg
Size: S-M/L-XL/XXL
Next Revision
The user must read and observe the Instructions for Use!
Standards Documentation to which the equipment complies
Manufacturer Mittelmann Sicherheitstechnik GmbH & Co. KG
Identification number of the quality inspection body
Manufactured in the year
Serial number of the full body harness
Maximum permitted body weight of user
States the size of the safety harnesses
Statement of when the next inspection must take place
Fall Arrest Attachment Element
Type Designation
Type Designation