F9 Parámetros De Operación Programable - AEA SANYU SY5000 Serie Manual De Instrucciones

Variador vectorial de alta performance
Tabla de contenido

Publicidad

When the feedback pressure is higher tan set pressure, the frequency drops to the pump lower limit frequency, after
pumping delay time after the pump.
Sensor range
F8.25
0.000 ~ 60.000MPa
Pressure setting (MPa)
F8.26
0.0 ~ 3600.0s
This parameter is used in the "one drag three constant pressure wáter supply", the main pump start delay
when switch between maim pump and Auxiliary pump
Uxiliary pump start mode selection
F8.28
0 ~ 1
0: Directly
This method is mainly used for 7.5KW below the pump, when the pressure is not enough direct power
frequency start.
1:Softly
The way is mainly used for a drag two, two pumps low frequency start.
Proportional gain KP2
F8.29
0.01 ~ 100.0S
Integral time Ti2
F8.30
0.01 ~ 10.00s
Derivative time Td2
F8.31
0.01 ~ 10.00s
PID Upper limit cutoff frequency
F8.32
(F8.33) ~ 300.00Hz
PID Upper limit cutoff frequency
F8.33
-300.00 Hz ~(F8.32)
Note: When the frequency is lower tan -99.99Hz, set F0.18 one´s place to 1
Sleeping frequency
F8.34
0.00Hz ~ upper limit frequency
F9 Parámetros de operación programable
Modo de funcionamiento del PLC
F9.00
0~3
0:detención tras un solo ciclo
Como se muestra en Fig.F9-1, el driver se detiene después de un solo ciclo. Empezará a dar otro comando. Si el tiempo
de operación es 0 en algún segmento, el driver saltará a otro segmento.
10.000
0.3
5.00
0.05
0.00
50.00
0.000
0.00
95
0
0

Hide quick links: