WARNING: the anti-tear rubber element must never be completely
compressed. Scrupulously check that the rubber does not become
totally compressed during operation.
6) ELECTRICAL INSTALLATION SET-UP (Fig.16)
M)
Actuator
Ft)
Transmitter photocell
Fr)
Receiver photocells
T)
1-2-4 channel transmitter.
Arrange for the connections of accessories and safety and control devices
to reach the motor unit, keeping the mains voltage connections clearly
separate from the extra low safety voltage connections (24V) by means of
the appropriate cable holder (fig. 8 ref. 5P1).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway
(fig. 8 ref. 5C1).
7) VENERE D Control panel (Fig.17)
Supply to accessories: ..................................................24V~ (180mA max)
.............................................................................24V~ Vsafe (180mA max)
Torque limiter setting:..............................................on closing and opening
Automatic closing time:..........................................................from 1 to 180s
Blinker connection:...............................................................24V~ max 25W
Service light switching-on time:..............................................................90s
Incorporated rolling-code radio receiver:..................frequency 433.92 MHz
Coding:.......................................................................rolling-code algorithm
No. combinations:...........................................................................4 milliard
Antenna impedance:............................................................50Ohm (RG58)
Max no. radio controls to be memorised:..................................................63
Slow-down distance:................closing: ~24 cm ................opening: ~24 cm
Fuses:......................................................................................see figure 17
7.1) Terminal board connections (Fig.17)
WARNINGS - For wiring and installation operations, refer to the current
standards and good technical principles.
The wires supplied with extra low safety voltage (24V) must be kept physi-
cally separate from the low voltage wires, or else they must be provided with
adequate additional insulation of at least 1mm.
The wires must be clamped by an extra fastener near the terminals, for
example by bands.
TERMINAL
DESCRIPTION
JP2
transformer wiring
JP10
motor wiring
1-2
Antenna input for integrated radio-receiver board
(1: BRAID. 2: SIGNAL).
3-4
START input (N.O.)
3-5
STOP input (N.C.) If not used, leave the jumper inserted.
3-6
PHOTOCELL input (N.C.) If not used, leave the jumper
inserted.
3-7
FAULT input (N.O.)
Input for photocells provided with checking N.O. contact.
8-9
24 V~ output for blinking light (25 W max).
10-11
24V~ 180mA max output – power supply for photocells
or other devices.
12-13
24V~ Vsafe 180mA max output – power supply for checking
photocell transmitters.
14-15
Gate-open warning light output (N.O. contact)/2nd radio
channel
16-17
PARTIAL OPENING input (N.O.)
8) PROGRAMMING
The control panel provided with a microprocessor is supplied with function
parameters preset by the manufacturer, suitable for standard installations.
The preset parameters can be changed by means of the programmer with
an incorporated display or by means of a universal palmtop programmer.
In the case where programming is carried out by means of a universal palmtop
programmer, carefully read the specific instructions for a universal palmtop
programmer and proceed as follows.
Connect the universal palmtop programmer to the control unit by means of
the UNIFLAT accessory. Enter the "CONTROL UNITS" menu, and the "PA-
RAMETERS" submenu, then scroll the display screenfuls using the up/down
arrows, and set the numerical values of the parameters listed below.
INSTALLATION MANUAL
For the function logics, refer to the "LOGIC" submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the "configuration" paragraph.

8.1) CONFIGURATION

The display programmer is used to set all the VENERE D control panel
functions.
The programmer is provided with three pushbuttons for menu scrolling and
function parameter configurations (Fig. 2):
+
menu scrolling/value increment key
-
menu scrolling/value reduction key
OK
Enter (confirm) key
The simultaneous pressure of the + and – keys is used to exit the active
menu and move to the preceding menu.
If the + and – keys are pressed simultaneously at the main menu level (param-
eters, logics, radio, language, default, autosetting, end-of-stroke adjustment),
programming is exited and the display is switched off (the END message is
displayed).
The modifications made are only set if the OK key is subsequently pressed.
When the OK key is pressed for the first time, the programming mode is
entered.
The following pieces of information appear on the display at first:
-
Display Software version
-
Control unit Software version
-
Number of total manoeuvres carried out (the value is expressed in
thousands, therefore the display constantly shows 0000 during the first
thousand manoeuvres)
-
Number of manoeuvres carried out since the latest maintenance opera-
tion (the value is expressed in thousands, therefore the display constantly
shows 0000 during the first thousand manoeuvres)
-
Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first
menu (parameters, logics, radio, language, default, autosetting, end-of-stroke
adjustment) can be accessed directly.
Here follows a list of the main menus and the respective submenus avail-
able.
The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
8.2) Parameter Menu (PARAM)
-
Automatic Closing Time (TCA) [ 40s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds.
-
Opening torque (open torque) [ 75% ] Set the motor torque value
between 1% and 99%.
-
Closing torque (cls. torque) [ 75% ]
Set the motor torque value between 1% and 99%.
WARNING: Check that the impact force value measured at
the points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
-
Partial opening ( part. open ) [1,0 m]
Set the numerical value for partial opening from 10 cm (000,1) to 6 m.
(006.0).
-
Zone (zone) [ 0 ]
Set the zone number between a minimum value of 0 and a maximum
value of 127. See paragraph 11 on "Serial connection".
8.3) Menu Logiche (LOGIC)
-
TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
-
3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A start impulse has the following effects:
door closed: ..............................................................................opens
on opening: .............................stops and enters TCA (if configured)
door open: ............................................................................... closes
on closing: ..........................................stops and reverses movement
after stopping: ...........................................................................opens
OFF Disables 3-step logic.
-
Opening Impulse lock (Ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening phase.
-
Pre alarm (pre-alarM) [ OFF ]
ON
The blinker comes on about 3 seconds before the motor starts.
OFF The blinker comes on at the same time as the motor starts.
ENGLISH
1
BOTTICELLI VENERE D -