14) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed
automatically. There are different types of controls (manual, radio control,
magnetic card access etc.) depending on the installation requirements and
characteristics. For the various control systems, see the relevant instructions.
The automation device users must be instructed on control and operation.
15) ACCESSORIES
SM1
External release device to be applied to the cremone bolt already
fitted to the overhead door (fig.22).
SET/S External release device with retracting handle for sectional doors
measuring max 50mm (fig.23).
ST
Automatic bolt release device for spring-operated overhead doors.
Fitted to the control arm, it automatically releases the side door bolts
(fig.24).
16) MAINTENANCE
Before carrying out any maintenance operation, disconnect the system
power supply.
Periodically check the tension of the chain/belt (twice a year).
Occasionally clean the photocell optical elements, if installed.
Have a qualified technician (installer) check the correct setting of the
electronic clutch.
When any operational malfunction if found, and not resolved, disconnect
the system power supply and request the assistance of a qualified techni-
cian (installer). When the product is out of service, activate the manual
release device to allow the door to be opened and closed manually.
If the power supply cable is damaged, it must be replaced directly by
our company or our technical service department or by a technician
having similar qualification so as to avoid any risks.
16.1) FUSE REPLACEMENT (Fig.25)
WARNING! Disconnect the mains voltage.
Remove the rubber protection from the fuse-carrier. Remove the fuse (Fig.25,
Ref.A) to be replaced and replace it with a new one. After completing this
operation, re-fit the rubber protection.
17) SCRAPPING
Warning! This operation should only be carried out by qualified per-
sonnel.
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out by
type (electrical components, copper, aluminium, plastic etc.).
18) DISMANTLING
Warning! This operation should only be carried out by qualified personnel.
When the automation system is disassembled to be reassembled on another
site, proceed as follows:
Disconnect the power supply and the entire external electrical installa-
tion.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
0 -
BOTTICELLI VENERE D
INSTALLATION MANUAL

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Botticelli venere

Tabla de contenido