Beninca CP.PONY 115 Manual Del Usuario página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
Condominium function (IBL)
If used in condominiums, it may be preferable that further commands given during the opening phase are ignored.
This function can result useful if many users are involved, in a way to prevent several opening commands, given at the same
time, causing the movement to stop.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the IBL function is displayed.
Press the [PGM] button to enter the IBL regulation.
The display shows the current value of the IBL parameter.
2
ON
IBL mode activated
OFF
IBL mode deactivated (default)
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the IBL menu. To exit programming, press the [PGM] and [5] buttons
4
at the same time or, alternatively, remove the power supply or wait 60 seconds.
Selection of photocells functioning (PHCL)
It is possible to select the functioning mode of the photocells connected to the PHOT input. Normally, the photocells are active
only in the closing phase, to allow the access of the vehicle even when the gate is not completely open. If this intervention is also
desired in the opening phase, modify the parameter as follows:
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the PHCL menu is displayed.
Press the [PGM] button to enter the PHCL regulation.
The display shows the current value of the PHCL parameter.
2
Use the [5] key to select one of these values:
ON
Photocells active in the opening and closing phase
OFF
Photocells only active in the closure phase (default)
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the PHCL menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
Selection of direction of rotation of the motor (MINV)
The sliding gates can open by sliding to the right or to the left, as indicated in Figure.
SX
The direction of rotation may have to be inverted according to the position of the motor.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the MINV menu is displayed.
Press the [PGM] button to enter the MINV regulation.
The display shows the current value of the MINV parameter.
2
Use the [5] key to select one of these values:
C__O
Motor with opening to the right
O__C
Motor with left opening - default setting-
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the MINV menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
18
OPEN
DX
OPEN
OPEN
OPEN
SX
IBL
PMOT
on
off
PRG
5
PGM+
PHCL
PMOT
on
off
PRG
5
PGM+
DX
MINV
PMOT
o--c
c--o
PRG
5
PGM+

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

PonyPony 115

Tabla de contenido