Electrical connection
6.2
Model CTW with integrated water pump
A
NOTICE!
• The 12 Vg connection cable must have a cross-section of at least
0.75 mm
• The current consumption of the pump should not exceed 2 A.
• A 7.5 A automotive fuse is integrated in the toilet control.
➤ Connect the toilet via the main terminal block of the vehicle to its own power
supply.
➤ Make the plug connections between control and operating panel and the
cassette tank.
Circuit diagram for integrated water tank and water pump (fig. q, page 20):
No.
1
2
3
4
5
6
7
8
32
²
.
Designation
Reed switch: Tank status 3/4 full
Reed switch: Tank status 1/1 full
Micro-switch: Position of cassette tank
®
With SOG
only: Reed switch for SOG
®
With SOG
only: SOG
®
With SOG
only: SOG
Reed switch: Freshwater indicator
Internal water pump
®
control
®
control solenoid in the slide opening handle
®
fan
CT4000