Description of functions and controls

The controls of the machine are described here below
with reference to the following figure.
L1
E1
C2
I1
When the 'I1' ON/OFF switch is pressed the generator
turns on. After the internal diagnostic phase of about 7
seconds, on the first ignition the generator starts with
the following factory settings:
MMA mode
Set current of 50A
Reduced void voltage <15Vdc (VRD function)
The generator is now ready to use, and by turning the
'E1' encoder knob the welding current can be regulated
between a minimum of 5A to a maximum of 140A.
Press the 'I1' switch to turn the generator off. For a few
seconds the 'D1' display will show the message 'OFF,
the led 'L1' will start flashing blue and then the
generator will be completely turned off. If the generator
needs a cooling cycle (for a maximum of 10 minutes)
the fan will continue running to then turn off
automatically.
Depending on the colours, the 'L1' and 'L2' leds show
the following generator states:
Led 'L1'
Led 'L2'
Blue
blinking
Green
Green
Green
L2
D1
Green
C1
Green
Blue
Yellow
If a protection device triggers (alarm - Led 'L1' yellow)
the 'D1' display shows the device that has triggered:
A. 2
Overvoltage (shown the next time the generator is turned on
A. 4
after being turned off due to the device triggering)
When the generator is turned on there is a short-circuit
A. 6
between the fasteners '+' and '-' (e.g. rod pincers resting on
A. 8
A. 9
Welding process change
To change the welding process proceed as follows:
Press the 'E1' encoder knob for 2 seconds.
Select the welding process from the available ones
shown on the 'D1' display:
MMA (standard rod welding)
ALU (welding with specific parameters for aluminium
electrodes)
CEL (welding with specific parameters for cellulosic
electrodes)
TIG (TIG welding with LIFT start with current
adjustable between 5A and 150A.
Press the 'E1' knob to confirm (after 5 seconds with
no activity, it is confirmed automatically).
The chosen welding process is stored in the memory.
When the generator is turned back on, the default
settings will be the same as those when it was turned
off.
Page 16
MEANING and SOLUTIONS
-
Generator being turned on or off
The generator is on and ready in
White
Uo<15Vdc mode
The generator is on and ready in
Red
Uo=67Vdc mode
The Hot-Start, Arc-Force, Slope-Up
Blue
setting menu has been selected
When the welding current is being set it
shows when, presumably, the available
power limit will be exceeded that has
been set in the POWER menu (lower the
current value or increase the available
power value)
During welding the available power limit
set in the POWER menu has been
exceeded (lower the current level,
increase the available power level or
shorten the length of the welding arc)
The advanced setting menu has been
Blue
selected POWER, SLEEP, AUTO
POWER OFF, Uo, FACTORY
-
Alarm
Overheating
the part being welded)
Internal alarm (call the service centre)
Internal alarm (call the service centre)