Waste Water and Connection

4.8.1
Waste water system
The waste water system of the warewasher is a pumped drain
application.
4.8.2
Waste water connection
Pumped drain:
The outlet end of the waste hose of the pumped drain can be
trimmed to fit a variety of sizes of pipes / spigots.
The waste plumbing for this warewasher can be up to a
maximum height of 700mm from ground level:
Fit the waste hose of the warewasher to the existing waste
piping. Ensure that the waste hose is not kinked. Ensure that the
waste hose is fitted in such a way that it will not come off or out
of the existing waste piping during warewasher operation.
The waste water from the warewasher
must be disposed of down the foul drains
system, i.e. the drains from sinks and
WCs. The waste water from the
warewasher must not be connected to
the surface water drainage system.
A form of back flow prevention must be installed into the waste
water plumbing in accordance with local and national
regulations.
Ensure that no part of the waste hose
from the warewasher is higher than the
mark on the rear of the warewasher
(shown), when the warewasher is in
place.
Where the warewasher is fitted to a stand pipe, the Waste Hose
Hook should be used to help manage the hose.
4.9

Attaching Chemical Bottles

Warning!
Wear the correct Personal Protective Equipment,
e.g., gloves and goggles, when handling
chemicals and observe all safety notes and
dosing recommendations printed on the
packaging.
Caution
Only use commercial grade detergents and
rinse aids within the warewasher.
The chemical bottles should be placed in a safe, stable location
that is close to the warewasher and easily accessible in order to
check the levels and replace the bottles as needed.
A coil of PVC tubing is connected to each of the chemical pumps
inside the warewasher.
These tubes exit the rear of the warewasher and should be
routed to the chemical bottle locations. The tubes need to be
long enough to allow the bottles to be moved without the risk of
falling over. Excess tubing may be cut off.
Tubing colour
BLUE
CLEAR
Chemical
Rinse aid
Detergent