Descargar Imprimir esta página

Graf KLARO Serie Instrucciones De Montaje página 26

Separador de líquido ligero

Publicidad

Idiomas disponibles

Idiomas disponibles

2.3.2. Slope, embankment, etc.
During the installation of the tank in close proximity (<5 m) to a slope, mound or
embankment (greater than 5°), a statically calculated retaining wall must be built to
absorb the active earth pressure. The wall must exceed the tank dimensions by at least
500 mm and must have a minimum clearance of 1000 mm to the tank.
Saphir tank series
>1000
2.3.3. Ground water and cohesive (water-impermeable) soil (e.g. clay soil)
The tank must only be installed into groundwater/stratum water up to the levels specified
in the following table. If it is to be expected that groundwater/stratum water levels - even
if only occasionally - exceed these levels, it must be drained.
The drainage line may end up in a vertically installed DN 300 pipe, equipped with a
submersible pressure pump that drains the excess water. The pump must be inspected
in regular intervals.
Tankserie Saphir
Max.
Typ
NS3-300
NS3-400T, NS3-600,
NS6-600,
2. Installation conditions
Max.
max. groundwater
level [mm]
675
795
KLsepa.compact
Diamant tank series
Tankserie Diamant
Typ
NS 6-1300, NS 10-1300
NS 10-4000, NS 15-2000
h
1/2 h
max. groundwater
level [mm]]
575 (1/2 h)
700 (1/2 h)
25

Publicidad

loading