Waeco PerfectCharge IU152A Instrucciones De Montaje página 50

Ocultar thumbs Ver también para PerfectCharge IU152A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
Using the IU0U automatic charger
10.3
Conditioning the battery
To prevent any sulphation of the battery during prolonged non-use (during
the winter), it must be charged beforehand.
➤ If applicable, disconnect the starter battery from the charger.
➤ Connect the battery to be charged.
➤ Set the DIP switch (fig. 8 5, page 7):
– Switch 4: ON
– Wet batteries: Switch 3: ON
Gel/fleece batteries: Switch 3: OFF
➤ Set the main switch on the IU0U-automatic charger (fig. 2 1, page 3) to
"I".
✓ The battery will be charged for 8 hours (switch 3: ON) or for 16 hours
(switch 3: OFF) at the charging voltage which has been set.
When this time has passed, the IU0U-automatic charger automatically
switches to the retentionphase.
NOTE
I
A slight overcharging could occur, in wet batteries indicated by es-
caping gases and in gel/fleece batteries by slight warmth.
➤ After conditioning, turn switch 4 on the DIP switch (fig. 8 5, page 7)
to "OFF".
You will thereby prevent any repetition of the conditioning caused by
switching the charger off and on again, which can damage the battery.
50
PerfectCharge
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido