Max power photovoltaic field
Nominal AC power
Max.AC power
Nominal DCV [V
Max. open DCV [V
MPPT range [V
Working range [V
Initial feed in voltage [V
System start-up voltage[V
Shutdown voltage [V
Max. input current per MPPT [A
Max input power per MPPT [kW]
Number of MPP Trackers
Minimum allowed PV generator insulation [M ]
DC Connectors
Operational voltage [V
Operational frequency [Hz]
AC connector
Current distortion
Power factor
Suggested min. wire area [mm
Maximum allowed wire area [mm
suggested magneto thermal protection
Suggested (optional) differential protection
Maximum η
European η
Protection degree
Operational / rated power temperature ° C
Heat Dissipation
Power consumption (Standby / Night)
Acoustic noise
Page 254
]
DC
]
DC
]
DC
]
DC
]
DC
]
DC
]
DC
DC
]
AC
2
Humidity

- APPENDIX -

Appendix

Electrical
Input
]
3 pairs of MC4 or Wieland PST 40I1
Output
]
2
]
Threephase 4 poles16A curve B or C
Environment
13kW
10kW
11kW
640
800
250 ~ 720
200 ~ 800
350
260
200
13
5.5
3
8
400
50
Screw terminal block (3P+N+PE)
<3%
>0.99
4
10
300mA type A
>96%
>94.5%
IP 65
-20 ~ +55 / -20 ~ +40
0 ~ 95% non condensing
Fan cooled heatsink
<30W / <5W
<45dB