Maintenance And Cleaning; Cleaning The Unit - Oase Aquarius Universal 800 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Prior to reaching into the water, disconnect the power supply to all units used in the water.
• Disconnect the power plug prior to carrying out work on the unit.
Attention! The pump must never run dry.
!
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Important:
● The unit switches on automatically when power connection is established.
1. Switching on: Connect power plug to the socket.
2. Switching off: Disconnect the power plug.
Attention! Risk of accident.
!
The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump automatically
switches on again once the motor has cooled down.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Before reaching into the water, disconnect all units located in the water from the mains.
• Disconnect the unit from the mains before performing any work on the unit.
• Secure the unit to prevent unintentional switching on.

Cleaning the unit

● Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the
pump when it is visibly soiled or when a drop in performance is detected. Clean the unit with warm water using a soft
brush.
● Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
● In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using warm water.
1. Dismantle the unit by unscrewing the 2 screws on both sides of
the pump.
2. Pull the back off of the pump to expose the impeller assembly.
3. Remove the impeller assembly by pulling on the back round plate
behind the impeller.
● Use a soft cloth or brush to clean the impeller assembly and the
inside of the impeller housing.
● Check parts for damages such as cracked shaft, cracks in the
bearing, and broken plastics. Replace parts if necessary.
● Reassemble in the reverse order.
3.
1.
2.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aquarius universal 1400

Tabla de contenido