NOTE:
If any tension is found between the front keypad assem-
bly and the wiring, open the keypad, reroute the wire and close
again. Repeat these steps until the keypad is closed properly.
Wiring
1. Before wiring the unit, ensure
that all power (AC trans-
former and battery) is discon-
nected from the control panel.
2. Connect the four Corbus wires
from the control panel (red,
black, yellow and green) to
the keypad terminals. Refer to
the diagram:
3. If programmed as an input, a
device - such as a door contact
- may be connected to the 'P/Z' terminal of the keypad. This
eliminates the need to run wires back to the control panel for
the device. To connect the zone, run one wire from the device
to the 'P/Z' terminal and the other wire from the device to the
B (black) terminal. For powered devices, run the red wire to
the R (positive) terminal and the black wire to the B (nega-
tive) terminal. When using end of line supervision, connect
the zone according to one of the configurations described in
the PowerSeries Neo Reference manual.
NOTE:
For UL/ULC installations, the zone input is a supervised
type (SEOL/DEOL). The supervision resistor is 5600Ω. If no EOL
supervision is used, there is a three foot maximum distance
required for the connected device. Use only in conjunction with
UL/ULC listed devices.
NOTE:
This initiating device connected to this input contact is
not to be used for medical or fire applications.
4. If the 'P/Z' terminal is programmed as an output, a small
relay (such as DSC model RM-1 or RM-2) or buzzer or other
DC operated device may be connected between the positive
supply voltage and the 'P/Z' terminal (max.load is 50mA).
NOTE:
For UL/ULC-listed installations, use UL/ULC listed
devices.
Apply Power
Once all wiring is complete, and the equipment is secured to the
building structure with at least two screws, apply power to the
control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see
the PowerSeries Neo Reference manual.
Program the Keypad
1. Press [*][8][Installer Code].
2. Use the [<][>] keys to navigate through the menus or jump
directly to a specific section by entering the section number.
Programming consists of toggling on and off options in each sec-
tion or by populating data fields. Toggle options are enabled or
disabled by pressing the corresponding number on the keypad.
For example, to enable toggle options 1 and 4, press the [1] and
[4] keys. All enabled options are displayed (see the following dia-
gram).
1. To input data, use the [<][>] keys to select a character then
press the keypad button for the number/letter.
2. Using the [<][>] keys, scroll to the next character and repeat
the procedure. For information on entering HEX data, refer to
the PowerSeries Neo Reference manual.
HS2LED/HS2ICN(RF)/
HS2LCD(RF)
____
____
RED
R
____
BLK
B
____
YEL
Y
____
GRN
G
To zone or
____
P/Z
PGM output
Language Programming
Enter [000][000]. Enter the two-digit number corresponding to the
language desired:
Table 2: Languages
01 = English
(default)
02 = Spanish
03 = Portuguese
04 = French
05 = Italian
06 = Dutch
07 = Polish
08 = Czech
09 = Finnish
Enroll the Keypad
Keypads can be enrolled automatically or manually. In either case,
the serial number of the device is used as an identifier.
NOTE:
power up, the keypad will display the message: Press any key to
enroll. Other keypads can then be enrolled from the first keypad.
Use one of the following enrollment options:
[902][000] Auto Enroll
When this mode is selected, the total number of keypads currently
enrolled is displayed on the keypad.
1. Enter [902][000] to begin the auto-enrollment of new key-
pads. As each device is enrolled, the keypad displays the
model type, serial number and slot assignment. Keypads are
assigned to the next available slot.
[902][001] Manual Enroll
To manually enroll individual keypads:
1. Enter [902][001] or use the [<][>] keys and press [*].
2. When prompted, enter the serial number of the keypad found
on the back of the device.
3. An error tone is sounded if an invalid serial number is
received. Once enrolled, the device model, serial number and
slot assignment are displayed. Keypads are enrolled into the
next available slot for the device. The slot assignment can be
changed using the [<][>] keys.
4. To cancel the enrollment of a module, press [#].
1
4
Toggle
(X)
<>
"Toggle name"
Y/N
10 = German
20 = Romanian
11 = Swedish
21 = Russian
12 = Norwegian 22 = Bulgarian
13 = Danish
23 = Latvian
14 = Hebrew
24 = Lithuanian
15 = Greek
25 = Ukrainian
16 = Turkish
26 = Slovak
17 = FFU
27 = Serbian
18 = Croatian
28 = Estonian
19 = Hungarian
29 = Slovenian
If there is no keypad enrolled on the system, once you
NOTE:
Once the maximum number of devices have been
enrolled, an error tone sounds and a warning message is displayed.
[902][002] – Module Slot Assignment (LED, LCD, ICON)
This section is used to change the slot number in which a module
is enrolled. To change the slot number:
1. Enter [902][002] or use the [<][>] keys and press [*].
2. Enter the serial number of the module.
3. When prompted, enter the new two-digit slot number. The
previous slot assignment is replaced with the new one. An
error tone sounds if an invalid slot number is entered.
[902][003] – Module Slot Assignment (LCD Keypad
Only)
Similarly to [002], this section is also used to change the slot num-
ber of a module. With this option, however, the serial number is
not required. To change the slot number:
1. Enter [902][003] or the use the [<][>] keys and press [*].
2. Use the [<][>] keys to locate the module then press [*] to
select.
3. Enter the new two-digit slot number. The previous slot
assignment is replaced with the new one. An error tone
sounds if an invalid slot number is entered.
[902][101] Unenroll Keypads
1. Enter [902][101] or use the [<][>] keys and press [*].
2. Use the [<][>] keys to scroll to the specific keypad to delete.
3. Press [*] to select the module and when prompted, press [*]
again to delete it.
[903][101] Confirm Keypad
To confirm the enrollment of individual keypads and to locate
them physically:
1. Enter [903][101] or use the [<][>] and press [*].
2. Use the [<][>] keys to scroll to the applicable keypad. The
module's serial number and slot number are displayed on the
keypad and the status LEDs on the device flash.
3. To confirm the keypad, press [*]. If communication with a
module is lost at the time of confirmation, a warning message
is displayed for 1 second before exiting the section.
Assign a Partition to the Keypad
The keypad must be assigned to a partition if supervision or key-
pad zones are required. Keypad assignments and keypad option
programming must be done at each keypad individually.
At each keypad installed on the system:
1. Press [*][8][Installer Code].
2. Enter [861]-[876]for Keypad Programming and Keypad Par-
tition Mask, corresponding to keypads 1-16.
3. Press [*] for partition assignment.
4. Enter 01 to 08 for partition assignment or use the [<][>] keys
to scroll to the specific partition If partitioning is not used,
enter [01]. For Global keypads, enter [00].
5. Press [#] twice to exit programming.
6. Continue this procedure for each keypad until all have been
assigned to the correct partition.
Program Labels (LCD keypads only)
1. Press [*][8][Installer Code].
2. Press [*] and use the [<][>] keys to scroll to Zone Labels and
press [*] again.The first zone is displayed. Alternatively,
enter, [000][001].