La Nordica WIND AIR Manual De Instrucciones página 27

Conexión kit ventilación opcional
Ocultar thumbs Ver también para WIND AIR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The upper part of the cover of each product is fitted with
outputs for connection of the air ducting pipes:
-.if.present,.remove.the.sheet.metal.perforated.panels.A.from.the.
outlets.at.which.the.air.ducting.pipes.are.to.be.connected;
Each pipe MUST NOT EXCEED 8 meters for forced ventilation,
it must be insulated with insulating materials to avoid noise
and heat dispersion.
The lengths of the ducting pipes should possibly be of equal
length to avoid different quantities of air and heat being
distributed by each outlet.
-. if. present,. remove. the. cast-iron. rings. and/or. the. sheet-metal.
perforated.panels.A from.the.outlets.where.the.air.ducting.pipes.
are.to.be.connected;
-.apply.20x2.mm..adhesive.gasket.B.–.0,6.m
-.secure.the.supplied.galvanised.fittings..C to.the.product.cover,.at.
the.outputs.to.be.channelled;
-.secure.the.ducting.pipes.D.to.the.galvanised.fittings.C.using.the.
supplied.hose.clamps.E;
-.in.the.case.of.channelling.a.product.with.four upper outputs,.it.
is.advisable.to.use the front ones.(see.example.A.in.the.figure).
where.most.of.the.heat.accumulates;
-. bend. the. two. ends. of. the. galvanized. support. brackets. 90°,.
where.the.motor.unit.of.the.Wind.Air.kit.will.be.fixed;
E
B
ENGLISH
A
D
C
A
A
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6016030

Tabla de contenido