COMMANDS REGULATOR
.IMPORTANT: switch off the control panel regulator and WAIT until the Led ON ends blinking BEFORE OPENING THE DOOR
when the appliance is functioning!
La NORDICA S.p.A. will not be responsible in case of smoke coming out from the ventilation outlets if this operation has
not been carried out !
The.control.regulator.allows.selection.of.the.speed.of.the.air.in.the.environment.and.the.desired.temperature.in.a.simple.and.intuitive.way..
The.regulator.must.be.positioned.far.from.the.vents.or.from.the.main.heat.source;.if.positioned.in.the.counter-hood.it.must.be.housed.in.a.low.
heat.point..The.simple.installation.is.guaranteed.by.housing.in.classic.recessed.electrical.boxes.fitted.in.common.buildings,.or.wall.mounted.
on.the.outside.of.the.wall.
The.regulator.manages.the.ventilation.with.two.modes.of.functioning.MANUAL/AUTOMATIC,.to.be.selected.by.pushing.the.relevant.buttons..
OPERATION of the regulator.
The.device.is.switched.on.and.off.by.pushing.the.on/off.button.1 ..
In.the.off.position,.the.light.point.of.the.ON.key.is.lit..In.this.mode.the.system.is.
in.Stand-by .mode,.therefore.always powered by the electric voltage.
By.pushing.the.on/off.button.1 ,.the.status.changes.from.the.OFF.state.to.the.
MANUAL.or.AUTOMATIC.operating.state.and.the.respective.LED.lights.up..In.
the.event.of.a.blackout,.the.AUTOMATIC.operating.mode.is.restored!
In.the.event.of.a.black out,.the.previously.set.operating.mode.is.restored!
Operation in MANUAL.
In.MANUAL.mode.the.fans.always.run.at.the.speed.set.by.the.user,.they.are.NOT.
subject.to.the.temperature.level.set.
Pushing. key. 2. switches. from. the. fan. SPEED. setting. mode. to. the. desired.
TEMPERATURE.setting.mode.in.the.room.where.the.controller.is.installed,.and.
vice-versa.
The.Speedis.set.when.LED.V.is.on.(Blue.colour).and.is.increased.with.key.3..
The.speed.value.can.be.read.from.the.blue LED.in.the.scale.to.the.side.
Key.3.increases.the.value.to.the.maximum.permitted.then.starts.again.from.the.
minimum.value.
AUTOMATIC operation.
The.AUTOMATIC.mode.is.useful.for.thermostating.the.room.where.the.regulator.
is. installed. as. well. as. ensuring. optimal. comfort. thanks. to. the. automatic.
modulation.of.hot.air.introduced.into.the.environment.by.the.fans.
The. user. sets. the. desired. temperature. in. the. environment. and. the. speed. of.
the.motors;.maintenance.of.these.settings.is.guaranteed.by.the.regulator.that.
automatically.controls.switching.on.and.off.of.the.fans.
Pushing. key. 2. switches. from. the. fan. SPEED. setting. mode. to. the. desired.
TEMPERATURE.setting.mode.in.the.room.where.the.controller.is.installed,.and.
vice-versa.
The.Speed is.set.when.LED.V.is.on.(Blue.colour).and.is.increased.with.key.3..
The.speed.value.can.be.read.from.the.blue LED.in.the.scale.to.the.side..Key.
3. increases. the. value. to. the. maximum. permitted. then. starts. again. from. the.
minimum.value.
The. Temperature.is.set. when.the.LED.C. is.on. (orange. colour). and. increases.
with.the.key.3..The.value.of.the.temperature.can.be.read.from.the.orange.led.
in.the.scale.to.the.side..Key.3.increases.the.value.to.the.maximum.permitted.
then.starts.again.from.the.minimum.value.
NOTE:. In. any. of. the. functioning. modes,. if. the.
temperature. of. the. air. coming. out. from. the.
ventilation. outlets. exceeds. the. alarm. limit,. the.
control.unit.increases.the.fans.speed.in.order.to.get.
rid.of.the.exceeding.heat.and.re-establish.the.security.
conditions.of.the.system.
.if this situation occurs too often, contact the nearest
Service enter.
ENGLISH
33