ELECTRICAL CONNECTION
.
THIS OPERATION MUST ALWAYS BE PERFORMED IN THE ABSENCE OF ELECTRICAL POWER SUPPLY !!
.The regulator and the system must be installed and connected by qualified personnel according to the regulations in force
(see.chapter.GENERAL.WARNINGS).
WARNING: the regulator and the power cord must NOT be in contact with hot parts.
CONNECTION:
Connect.the.power.supply.cable.of.the.regulator.to.a.bipolar.switch.with.a.contact.distance.of.at.least.3.mm.(230V.~.50Hz.power.supply,.
correct.connection.to.the.earthing.system.is.essential).
WARNING:. The. fAN. ELECTRIC. CONTROLLER. must. be. fed. into. the. mains. with. a. general. differential. circuit. breaker. upstream.
according.to.current.regulations..Correct.operation.of.the.command.is.only.guaranteed.for.the.specific.motor.for.which.it.was.built,.
at.MOST TWO MOTORS FOR EVERY REGULATOR.
.Improper.use.exempts.the.manufacturer.from.all.liability.
1 2 3 4 5 6 7 8 9
POWER.SUPPLY
ALIMENTAZIONE
230V~ 50Hz
230 V~ 50/60 Hz
1
Blue.-.Power.supply
2
Brown.-.Power.supply
3
Yellow/Green.-.Power.Supply
4
Yellow/Green.-.Motor
5
Yellow/Green.-.Motor
6
Blue.-.Motor
7
Brown.-.Motor
8
Blue.-.Motor
9
Brown.-.Motor
SND Blue.-.Temperature.probe
SND Brown.-.Temperature.probe
TEMPERATURE.PROBE
SND
M
M
MAIN.LINE.DIffERENTIAL.
SWITCH