configuration mode. Pushing the «+» button increases the target tem-
perature. Pushing the «–» button reduces the target temperature. The
setting is saved if no change occurs on the control panel for selection of
temperature for three seconds. The current room temperature is subse-
quently shown on the display.
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the
display. The ventilator remains switched on for 30 seconds at the lowest
level to cool down the heating element. The current temperature is then
measured approx. every 30 minutes (the fan runs for 1 minute at the
lowest level). The appliance switches on again if the room temperature
recorded drops below the set target temperature.
5. Cooling mode: the heating element switches off if the temperature is set
to 0 °C and the ventilator blows cool air out of the appliance. The LED
light (7) changes from red to blue. There is no temperature shown on the
display in cooling mode.
6. The heat output level can be changed over the left control panel (9)
«Power Level». The display flashes during the input process. Typing «+»
increases the output level. Typing «–» reduces the output level. The set-
ting is saved if no change occurs on the control panel for selection of
heat output level for three seconds. The current room temperature is
subsequently shown on the display.
7. Auto mode is activated by pressing the «Auto Mode» button (10). «Auto
Mode» is shown in the display. The preset target temperature of 22 °C
can be changed using the right-hand control panel for selection of tem-
perature (8). The heat output level is selected automatically in auto
mode - depending on the room temperature. The smaller the difference
between the room temperature and the target temperature, the smaller
the heat output level selected. We refer to this as «Adaptive Heat
technology and we have filed for an international patent. This allows
Anna big to make sure that the target temperature is reached, quickly
and efficiently, and maintained. Anna big thus prevents a sharp temper-
ature drop and prevents the appliance from being constantly switched
on and off. Auto mode is deactivated if the heat output level is changed
manually (9).
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the
display.
8. Switch off the appliance by pressing the On/Off button (6). The ventila-
tor remains switched on for 30 seconds at the lowest level to cool down
the heating element. The appliance saves the temperature input and the
heat output level even if the appliance is switched off.
9. Protection against overheating: the appliance is equipped with over-
heating protection which switches off the appliance in the event of a
technical fault or improper use (the ventilator continues to run for some
time at the lowest level to cool down the appliance). Should this occur,
rectify the fault or cease the improper use (e.g. 50 cm space around the
appliance, do not cover the appliance, set the appliance up in an upright
position). Once the appliance has cooled down it can be put back into
service.
»