Safety Interlock Wiring Diagram; Maintenance; Schéma De Verrouillage; Entretien - Graco 262004 Manual Del Usuario

Tabla de contenido

Publicidad

Parts / Pièces / Piezas / Delen / Teile
Safety Interlock Wiring Diagram / Schéma de verrouillage /
Diagrama de cableado de interbloqueo de seguridad /

Bedradingsschema beveiligingssysteem /

Schaltplan für Sicherheitsverblockung
Maintenance / Entretien / Mantenimiento / Onderhoud / Wartung
English
Interval
DAILY
AFTER THE FIRST 20 HOURS OF
OPERATION
WEEKLY
EVERY 100 HOURS OF OPERATION
YEARLY OR 500 HOURS

SPARK PLUG

52
10
123
120
Check engine oil level and fill as necessary.
Check hydraulic oil level and fill as necessary.
Check and fill the gas tank.
Drain engine oil and refill with clean oil.
Reference Honda Engines Owner's Manual for correct oil viscosity.
Remove engine air filter cover and clean or replace element. If operating in an
unusually dusty environment: check filter daily and replace, if necessary.
Replacement elements can be purchased from your local HONDA dealer.
Change engine oil. Reference Honda Engines Owner's Manual for correct oil viscosity.
Replace hydraulic oil and filter element. Use Mobil 1 (15W-50) synthetic oil and
Graco filter 245342.
Hydraulic Oil Replacement Procedure:
1.
Remove filter and allow oil reservoir to drain from filter base.
2.
Install new filter. Fill oil reservoir to top of baffle with Mobil 1 (15W-50).
3.
Open drive wheel release. Start engine and run at low rpm for 3 minutes.
4.
Close drive wheel release. Check oil level and top off to top of baffle.
Use BPR6ES (NGK) or W20EPR-U (NIPPONDENSO) plug. Gap plug to 0.028 to
0.031 in. (0.7 to 0.8 mm).
121
37
Action
122
ti10939a
312540M

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

262005Linedriver 262004Linedriver 262005Linedriver hd 262004Linedriver hd 262005Linedriver ... Mostrar todo

Tabla de contenido