Messages; Dc Controlpro; Error Messages Handytig 180 Dc Basicplus - LORCH HandyTIG 180 DC Basic Plus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46

Messages

17
Messages
17.1
Information and error messages HandyTIG 180 DC ControlPro
Code
Symptom
H06
EEProm write/read error
E01
Thermal overload
E02
Power section
E03
Current sensor
E06
Overvoltage
E07
Supply voltage 15V
E10
Torch/remote control
E14
Control panel
17.2

Error messages HandyTIG 180 DC BasicPlus

Symptom
LED mains 37 and LED malfunc-
tion 35 are not lit
LED mains 37 is lit and LED mal-
function 35 flashes
LED mains 37 is lit, but no welding
current
LED malfunction 35 is lit con-
stantly
12.10
Cause
Communication with EEProm faulty
Duty cycle exceeded
Fan defective
Power section start-up faulty
Current sensor defective
Mains voltage too high
Fault internal supply voltage
Remote control, torch or connections
defective
Component group control panel faulty
Cause
mains fuse defect
neutral, mains phase missing
machine error
ground cable not connected or de-
fect
electrode holder or torch not con-
nected or defect
machine is overheated, ED ex-
ceeded
Remedy
Switch machine off and on again, exe-
cute master reset
Allow switched-on machine to cool down
for a few minutes.
Switch unit off and on, fan must start up
for a short period, inform service.
Inform Service
Inform Service
Check mains voltage
Inform Service
Check or replace torch and remote con-
trol
Inform Service
Remedy
exchange mains fuse
check mains cable / mains extension cable
Turn off machine, wait until LED mains 12 is off,
turn machine on again If malfunction still persits,
contact Service
check ground cable, exchange if necessary
check electrode holder or torch, exchange if
necessary
let machine cool down in standby
- 39 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Handytig 180 dc control pro

Tabla de contenido