Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AIR REGULATION PRINCIPLE DIAGRAM AND DISK - ELECTRODES SETTING
After having installed the nozzle, check the correct position of the
electrodes and disk according to the following levels. It's adviseable
to check levels
after every intervention on head.
To prevent damage to the support or the pre-heater effect
nozzle assembly/disassembly tasks with the aid of a wrench
and counter-wrench.

PUMP PARTICULER SUNTEC AT3 45C 9558

BTL 4P
BTL 6P
BTL 10P
1
LOW PRESSURE REGULATOR (1ST FLAME) 10 BAR
2
HIGH PRESSURE REGULATOR (2ND FLAME) 22 BAR
3
SUCTION
4
RETURN
5
POURGE POINT (1/8")
6
VACUUM TEST POINT (1/8")
7
DELIVERY TO NOZZLE
8
PRESSURE OUTLET FOR 2ND FLAME ONLY
(CONNECTION POINT 1/8")
9
1ST FLAME SOLENOID VALVE (NORMALLY CLOSED)
10
2ND FLAME SOLENOID VALVE (NORMALLY OPEN)
11
PRESSURE OUTLET FOR 1ST AND 2ND FLAME
(CONNECTION POINT 1/8")
The pump is preset at a 10 bar pressure (1st flame)
and 22 bar (2nd flame).
11 / 16
0006080762_201309
A
B
C
D
3
0
6
2,5
3
2
6
3
3
2
6
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl 6pBtl 10p

Tabla de contenido