8
Technical data
Purifying respirator
Operating conditions
Temperature
Relative humidity
Volume flow
Operating life with single
battery charge (full charge)
Protection category
Weight
Belt unit
Particle filter
Combined filters
Approvals
Purifying respirator
Half mask
Full face mask
Particle filter
Combined filters
Protection levels
Charger
Operating conditions
Temperature
Relative humidity
Voltage
Power consumption
Protection category
Tests
Masks
See the corresponding Instructions for Use.
Panorama BelAir® GC - RA
o
o
10
C to 50
C
max. 90 % relative humidity
min. 120 L/min
min. 8 hours
IP 54
approx. 1300 g (without
Filter)
approx. 150 g
approx. 800 g
EN 12942:1998+
A1:2002+A2:2008
EN 140
EN 136
EN 12942:1998+
A1:2002+A2:2008
EN 12942:1998+
A1:2002+A2:2008
see Page 10
o
o
0
C to 50
C
max. 95 % relative humidity
220/230 V – 50 Hz
5 VA
IP 20
VDE 0700, SEV, S, D, Fi,
ÖVE, GS mark
9
Order list
Name and description
Panorama BelAir GC-RA
incl. charging cable, excluding filter and mask
BelAir 55 TM3 A2B2 P R SL
BelAir 55 TM3 B2K2Hg P R SL
BelAir 33 TM3 P R SL
Prefilter
Prefilter cover BelAir 33
Prefilter cover BelAir 55
Filter sealing plug
Shower cap BelAir 33/55
Carrier strap
Charger
X-plore 6300 - EPDM - PMMA - RA - K/bl
X-plore 6570 - Si/bl - PC - RA - K/sw
X-plore 6570 - Si/ge - L - RA
X-plore 4740 - Si - ML
X-plore 4740 - SI - SM
X-plore 4740 - TPE - ML
Testor 2100
Sealing plate GC
Pliers
Pliers
Sekusept Cleaner
Technical data
Order no.
R 53 380
67 38 898
67 38 899
67 38 900
67 36 300
67 36 413
67 36 412
67 36 352
R 52 981
R 53 643
64 30 720
R 55 800
R 55 790
R 55 850
R 55 874
R 55 875
R 55 876
R 53 400
R 53 129
16 13 391
R 53 239
79 04 071
15