9.3
Connecting the 230 V power cable
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 3, page 3)
to the 230 Vw input jack ig 5 6, page 4).
➤ Connect the safety plug to the 230 V AC mains.
9.4
Connecting the 230 V output cable
WARNING!
!
Before connecting the 230 Vw output cable, make sure the inverter
is switched off at the main switch.
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 2, page 3)
to the 230 Vw output jack ( ig 5 5, page 4).
9.5
Connect external switch to turn device on and off
NOTE
I
 Connect the external switch to the inverter using a connection
cable with Western telephone jack. Observe the PIN configura-
tion on the plug for the connection cable.
 Use cables with a cable cross section of 0.25 – 0.75 mm².
You can use the following as an external switch:
 external switch, voltage supply from the inverter: fig. 7, page 5
 Control unit with relay or transistor circuit (TR): fig. 8, page 5
 external switch with voltage supply from the battery (BAT) of the vehicle:
fig. 9, page 5
 external switch with its own voltage supply (DC POWER) e.g. from the ig-
nition: fig. 0, page 5
➤ Set the main switch (fig. 5 3, page 4) to "OFF" and make sure that the
connection for the remote control (fig. 5 12, page 4) is not assigned.
➤ Set the main switch (fig. 5 3, page 4) to "REMOTE".
➤ Cut a connection cable to size.
➤ Connect the external on/off switch with the connection cable on the re-
mote port (fig. 5 12, page 4).