Using the inverter
Setting the mains frequency
WARNING! Danger of electrocution
!
Only adjust the S3 DIP switch when the respective frequency for
the output voltage should be used.
You can set the mains frequency using the S3 dip switch.
Net frequency
50 Hz
60 Hz
Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches.
In this way, the battery you connect to the inverter is not discharged as quick-
ly.
The inverter operates in energy-saving mode as long as the required power
is below the set level. If the required power exceeds the set level, the inverter
works in normal mode.
The values to be set on your inverter can be found in the following table:
Energy-saving mode
Off
2%
3%
4%
5%
6%
7%
8%
46
DIP switch
S3
Off
On
DIP switch
S4
S5
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
SinePower
S6
Off
Off
Off
Off
On
On
On
On
EN