1.
BURNER DESCRIPTION
One stage light oil burner.
2
10
4
1 – Control-box
2 – Reset button with lockout lamp
3 – Air regulation unit
4 – Motor
5 – Flame tube
6 – Flange with insulating gasket
1.1 EQUIPMENT
Flange with insulating gasket . . . . . . . . No. 1
Screw and nuts for flange . . . . . . . . . . No. 1
Grommet . . . . . . . . . . . . . . . . . . . . . . . No. 1
Flame tube . . . . . . . . . . . . . . . . . . . . . No. 1
1.2
ACCESSORIES
DIAGNOSTIC SOFTWARE KIT
A special kit is available that detects the life of the burner through optical connections with a PC showing
the duty hours, number and types of lockout, control box serial number etc...
Do the following to display the diagnostic:
Connect the kit supplied separately to the appropriate socket on the control box.
The information is read after the software program in the kit is booted.
REMOTE RESET KIT
The burner is fitted with a remote reset kit (RS) consisting of a connection to which a button can be con-
nected up to a distance of 20 meters.
For the installation, remove the protection block installed in the factory and install the block that is supplied
with the burner (see wiring diagram on page 7).
3221
Fig. 1
11
3
5
8
6
7 – Light oil pump
8 – Flue gases slotted holes
9 – Heater connection fixing nut
10 – Air intake grid
11 – Slot regulation screw
12 – Capacitor
Screws and nuts for flange to be fixed to boiler . No. 4
Flexible oil pipes with nipples . . . . . . . . . . . . . . . No. 2
7 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
2
GB
9
D7295
1
12
7