IntelliFlo
VS Operator Control Panel
®
The IntelliFlo
VS operator control panel provides manual speed controls for the pump. There are four
®
preset speed buttons that can be selected. The Up and Down button is used to adjust the pump speed.
The selected speed can be saved and assigned to one of the speed buttons.
Controls and LEDs
Speed 1, Speed 2, Speed 3, and Speed 4 button/LED:
1
desired preset pump speed. The pump preset speeds are: Speed 1 (750 RPM), Speed 2 (1500 RPM),
Speed 3 (2350 RPM), and Speed 4 (3110 RPM). The speed button LED is on when the selected
button is pressed. If the pump is running and the Up/Down button is used to adjust the speed, the
selected speed LEDs will go off.
While the pump is running, press the Up or Down button to increase or decrease
2
Up/Down button:
the pump speed. To save the new pump speed, press any one of the four speed buttons for three
seconds to assign the speed to the selected button (the LED be on). Four adjusted pump speeds
can be assigned to the speed buttons. When the pump is using an adjusted speed and the pump is
powered down, the next time the pump is powered up the pump will use the same speed.
Starts the pump using a selected or adjusted speed. This LED is on when the pump
3
Start button/LED:
is running.
Press this button to stop the pump.
Stop button:
4
This green power LED is on when IntelliFlo
On LED:
5
This LED is on when an error condition occurs. This green LED will flash a certain
Alarm LED:
6
number of times indicating a specific error condition. For the alarm LED flash sequence, refer to
"Alarm and Warning LED Sequence," Section 5.
1
2
5
6
3
4
Press one of the speed buttons to select the
VS is powered up.
®
9