The chimney should be one metre higher than the
highest part of the house. If you need to increase the
draw, extend the length of the chimney.
At least 1
metre higher
INCORRECTO
Incorrect
Chimney covers must not affect chimney draw.
INCORRECTO
Incorrect
 It is advisable to clean the chimney at least
once a year.
In order to access the chimney for cleaning purposes,
observe the following instructions:
a)
Remove
the
instructions described in chapter "cleaning".
b)
Once the deflection plate has been removed, you
will be able to access the chimney. Clean the conduit
using a special chimney brush with a weight as
described in fig. 1.
These steps must be performed whenever the device
has been unused for a long period of time to ensure
no blockage exists before lighting it.
Fig. 1
Mínimo 1 m.
por encima
CORRECTO
Correct
(Ø)
CORRECTO
Correct
deflection
plate
(follow
 The joints of the pipes that form the chimney, in
the case of metal pipes, must be sealed with refractory
putty.
upwards to avoid any possible creosote from leaking out.
special double insulated pipes for solid fuels.
2.2.5 Installation using existing chimneys.
When using existing chimneys, it is advisable to place
one or two metres of metal pipe inside the existing chimney
and ensure that the gap between the brickwork chimney
and the pipes has been sealed (see figure).
The inside section of the chimney must be perfectly
insulated so that it is capable of resisting the high
temperatures reached by the insert fireplace.
Insulation should be placed on the internal walls,
allowing air to flow around the insert fireplace. Never place
insulations around the insert fireplace; it may be
damaged if heat is unable to dissipate. The metal chimney
Mínimo
should not be wrapped with insulating fibre.
Equal to Ø
igual al Ø
Internal insulation must not prevent the passage of
at least
air through the hood ventilation grilles.
Insulating fibre used inside must resist high
temperatures and must not produce any odour when
heated.
If the chimney should catch fire (an excessive
accumulation of creosote may catch fire), close all air input
to the device (primary and secondary) and even close air
input to the room where the device has been installed. This
will cause the flame to go out by themselves.
the
meters
IMPORTANT
Never let the full weight of the chimney lie on the Insert
Fireplace. This could damage it.
The female coupling of the pipes must face
External metal chimneys must be built with
1-2
Seal