Function lights
Signal
Constant green
Flashing green
Constant red
Flashing red
5.4
Battery handling
•
Only insert batteries into the charger once they have cooled down.
•
GESIPA
batteries can be charged approx. 1000 times.
®
•
Do not insert the battery into the charger after each use.
•
If battery autonomy becomes significantly shorter despite proper recharging, the battery
shoukd be replaced.
•
Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10°C to 50°C.
GESIPA
batteries have a display showing battery life in percent. Press the button in the dis-
®
play to activate the green LED lights for approx. 5 seconds.
*****
Battery full charged
****
Battery capacity approx. 80%
***
Battery capacity approx. 60%
**
Battery capacity approx. 40%
*
Battery capacity max. 20%, charge soon
5.5
Environmental protection
If batteries need to be replaced, please observe the following:
•
Take used GESIPA
•
Never throw discarded batteries into the waste, into fire or into water!
Meaning
Battery is charged / top-up charging
Charging
Charging temperature out of range (battery too hot or too cold)
Battery is defective or wrong battery (different manufacturer)
batteries back to your agent or to GESIPA
®
for recycling.
®
GB