Error 91
If, during the initialisation procedure, the control unit fails the
exterior photocell test, the display shows the message
Check the photocell connected to the PHOTO input is working.
PLEASE NOTE: This abnormality does not delete data
acquired using the initialisation procedure
Error 92
If, during the initialisation procedure, the control unit detects an
obstacle during movement of the gates, the display shows the
Er92
massage
Ensure there are no obstacles within the gate movement area and
repeat the initialisation procedure.
Error 93
If, during the initialisation procedure, the display shows the
Er93
massage
, this means the SLAVE motor is connected with
incorrect polarity.
Check the SLAVE motor connection and repeat the initialisation
procedure.
Error 94
If, during the initialisation procedure, the control unit fails to
detect the presence of the SLAVE motor, but the operator has
indicated this to be present, the display shows the message
Check the SLAVE motor connection and repeat the initialisation
procedure.
Er91
Er94