Place the cap on the tank.
5
Cut at 100 mm, insert the "T" and connect
the smallest section tube to this marked with
Y tape (ensure that the radius of the curve is
sufficient so as to prevent constrictions).
a- Connect the pump impulsion tube.
6
b- Connect the 2-way box of the float.
c- Connect the 2-way box of the pump.
The outflow tube must be vertical, without any
7
horizontal sections, loops or constrictions, in
order to allow the water to fall into the tank
whilst preventing accumulation in the tray
and subsequent spillage to the exterior, thus
emptying the tank of water.
IMPORTANT: DO NOT CUT the excess
cabling and secure it (rolled up) behind the
water tank.
In the event of error, connect in the original
position in order to prevent irreparable damage
in the electronic control.
"T"
(b)
(c)