AIR VENT
FILTERING OR DUCTING ?
Your cooker hood is designed to be used only in filtering version.
The aspirated air will be degreased and deodorised before being fed back into the room.
The filtering system provides a High Performance activated charcoal filter
Note: due to its technical characteristics, it is not possible to use the hood in the extraction mode
Important! To proceed with the installation it is necessary to use a tube of flexible type
Filter version
The aspirated air will be degreased and deodorised before being fed back into the room.
In order to use the hood in this version, you have to install a system of additional filtering based on activated charcoal.
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and a light switch to control cooking area lights.
To select hood functions, simply touch the controls:
T1. Button ON/OFF suction motor
T2. Button to select medium suction speed (power)
T3. Button to select high and intensive suction speed (power)
Press once to select high suction speed (power) (LED T3 on);
Press again to select intensive suction speed (power) (LED T3 flashing).
Note: The intensive suction (power) speed lasts for approximately 5 minutes, then the high suction speed (power) is set
automatically.
T4. Automatic shutdown button (Timer) and saturation indicator for charcoal filter:
Automatic shutdown:
Press this button to set the automatic shutdown of the active suction speed (power):
Silent suction speed (power): 20 minutes
Medium suction speed (power): 15 minutes
High suction speed (power): 10 minutes
Saturation indicator charcoal filter
When flashing, perform maintenance of the charcoal filter, if installed, then keep the button T1 pressed for a long time to stop the
flashing.
T5. Button to select 'silent' suction speed (power) and saturation indicator for grease filter
Note: when flashing, perform maintenance of the grease filter; then keep the button T1 pressed for a long time to stop the flashing.
T6. Button ON/OFF lighting
T2+T3+T4 flashing: automatic operation under high temperature conditions (see relevant paragraph)
Activation of the charcoal filter saturation indicator
This indicator is normally deactivated. To activate it, proceed as follows:
With the hood off, press and keep pressed simultaneously T2 and T3: T3 starts flashing first, then T2 as well, to indicate successful
activation.
Deactivation of charcoal filter saturation LED: repeat the operation described above; T3 and T2 start flashing, then only T3 to indicate
successful deactivation.
Automatic operation under high temperature conditions
The hood is equipped with a sensor which detects the temperature. When this becomes too high, the sensor automatically turns on the
medium suction speed (power). The hood turns off as soon as the temperature detected by the sensor is lowered significantly.
53