To prevent accidents and personal injury, all
the equipment must be correctly installed,
correctly operated and correctly serviced.
SWITCHING ON THE
MACHINE
Connect the power supply cable (A, Fig.
9b) supplied with the machine from the
external electrical panel located on the
rear side of the wheel balancer body to
the mains.
Switch on the machine using the switch on
the rear side of the body (B, Fig. 9b).
The wheel balancer performs a checking
test (all the LEDs illuminate), and if no
faults are detected, a beeper sounds and
the cycle status initially active is displayed,
as follows:
- active balancing mode: dynamic (STD);
values displayed : 000 000;
- grams displayed in units of 5 (or 1/4 of an
ounce);
- sensor rounding-off active (if automatic
sensor is present);
- default geometric values: width = 5.5",
diameter = 14", distance = 150 mm.
Now the operator can set the data of the
wheel to be balanced or select one of the
programmes available.
User manual S 63
WHEEL DATA
Wheel data entry for wheel bal-
ancers with automatic sensors
To enter the distance, diameter and width
values automatically, proceed as follows:
- bring the automatic internal measuring
arm (1, fig. 7) into contact with the inner
side of the rim as shown in fig. 10/10a
and at the same time bring the automatic
external measuring arm (2, fig. 7) into
contact with the outer side fig. 10b.
9b
ENTRY
10
10a
53