•
The limit switches must be connected before the electric cylinder, since
a query is not carried out via the cylinder. As a result, there is a risk of
mechanical damage without a limit switch query by your control.
•
When switching the electric cylinders, take particular care that the
generator short-circuit brake has been selected for switching the motor.
Otherwise, the electric cylinder may run to "block" and be destroyed.
Control LZ 60 "b" (examples)
e.g. P6KE51C
Fig. 1: Connection for controlling per button
7. Working life
PLC
Hall sensor
e.g. P6KE51C
Fig. 2: Connection for controlling per PLC
53