7.4.4 Hall sensor evaluation/signal paths

Extended direction
Channel
A
B
External pull-up resistor required (normally 10 k) (see example diagram above)
Hall sensor supply voltage 5 V...24 V
Current consumption: 5 mA quiescent current per sensor
Maximum hall sensor output current 100 mA
Frequency of the hall sensor impulses at 24 V max. 100 Hz
Frequency of the hall sensor impulses at 36 V max. 150 Hz

7.4.5 Hall sensor resolving power

Type
Version
LZ 60 S
a/1500 N
LZ 60 S
b/3000 N
LZ 60 S
f/4000 N
LZ 60 P
b/2000 N
LZ 60 P
c/1000 N
LZ 60 P
e/3000 N
LZ 60 P
f/4000 N
With an edge evaluation, the accuracy of the evaluation is doubled. This principle is used with
RK synchronous controls.
Channel
+DC
A
GND
+DC
B
GND
Number of pulses
per motor
revolution
2
2
2
2
2
2
2
7. Working life
Retracted direction
Gear X:1
Spindle pitch
20
16
20
4
20
2.25
8.25
4
16.5
16
16.5
4
16.5
2.25
Accuracy
0.4 mm
0.1 mm
0.06 mm
0.24 mm
0.48 mm
0.12 mm
0.07 mm