VHW200 - VHW201 - VHW210 - VHW211
Power cable
Type and section
Insulation
Minimum external diameter
Blower connection cables
Type and section
Cable clamp size
Temperature
The indicated temperature is the minimum operating
temperature.
Circuit breaker
The circuit breaker must be chosen according to the current
rating indicated on the vacuum cleaner plate.
Here below there is a list of the suggested ranges for circuit
breakers according to the models:
Model
VHW200
VHW201
VHW210
VHW211
Extensions
If an extension cable is used, make sure it is suitable for the
GB
power input and protection degree of the vacuum cleaner.
Minimum section of extension cables:
Maximum length = 20 m
Cable = FROR
Max power (kW)
Minimum section (mm
C411
VHW 200
VHW 201
VHW210
VHW211
4G - 2,5mm
450/750V
10 - 15mm
VHW 200
VHW 201
VHW210
VHW211
4G - 2,5mm
M25
70° C
Circuit breaker
range
1,1 ÷ 1,6A
2,2 ÷ 3,2A
VHW 200
VHW 201
VHW210
VHW211
1
)
1.5
2
Sockets, plugs, cable clamps, connectors and
installation of the extension cable must maintain the IP
protection degree of the vacuum cleaner, as indicated
on the data plate.
2
The vacuum cleaners are safe only if equipped with a
circuit breaker protection.
Otherwise there is a risk of electric shock and fire.
The vacuum cleaner's power socket must be protected
by a differential circuit-breaker with surge current
limitation, that shuts off the power supply when the
current discharged to the ground exceeds 30 mA for
2
30 msec. or an equivalent protection circuit.
Never spray water on the vacuum cleaner: this could
be dangerous for persons and could short circuit the
power supply.
Comply with the safety regulations governing the
materials for which the vacuum cleaner is used.
Dry applications
The supplied filters and the bag (if applicable) must be
installed correctly.
Comply with the safety regulations governing the
materials for which the vacuum cleaner is used.
Maintenance and repairs
Disconnect the vacuum cleaner from its power source
before cleaning, servicing or replacing parts; the
vacuum cleaner cable plug/terminals must be removed
from the power source.
■ Carry out only the maintenance operations
described in this manual.
■ Use only original spare parts.
■ Do not modify the vacuum cleaner in any way.
Failure to comply with these instructions could
jeopardize your safety. Moreover, such action would
immediately void the EC declaration of conformity/
incorporation issued with the device.
6
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
[ NOTE ]
WARNING!
WARNING!
04/2017