Replacing The Plug Fuse (12/24 V); Cleaning And Maintenance - Waeco Bordbar CDF-11 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
_CDF-11.book Seite 28 Freitag, 24. September 2010 1:57 13

Cleaning and maintenance

5.13

Replacing the plug fuse (12/24 V)

➤ Pull the adapter sleeve (fig. 3 4, page 3) off of the plug.
➤ Unscrew the screw (fig. 3 5, page 3) out of the upper half of the housing
(fig. 3 6, page 3).
➤ Carefully raise the upper half of the housing from the lower (fig. 3 1,
page 3) half.
➤ Take out the contact pin (fig. 3 3, page 3).
➤ Replace the defective fuse (fig. 3 2, page 3) with a new one that has the
same rating (T8A 32V).
➤ Re-assemble the plug in the reverse order.
6
Cleaning and maintenance
Caution!
e
Before cleaning or maintaining the cooler, pull the cable out of the
socket or the cigarette lighter.
Caution!
a
Never clean the device under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during clean-
ing as these can damage the device.
Never use brushes, scouring pads or hard or pointed tools to re-
move ice or to loosen objects which have frozen in place.
➤ Occasionally clean the device interior and exterior with a damp cloth.
28
BordBar CDF-11

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido