Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
European Gas Category:
Gas Flow Rate:
Supply Pressure (G20):
Factory Adjusted Pressure (G20):
Factory set for Australia/New Zealand NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
Supply Pressure (G20):
Adjusted Pressure (Test Point Pressure):
Nominal Hourly Gas Consumption:
With Australia L.P. Gas Conversion Kit: Injector Size: 1.40 mm Heat input gross: 6.54 kW
Country:
L.P. Supply Pressure:
Adjusted Pressure:
Nominal Hourly Gas Consumption:
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.0 kW
Country:
European Gas Category:
Gas Flow Rate:
Supply Pressure (G25):
Factory Adjusted Pressure (G25) :
Supply Pressure (G30/G31):
Factory Adjusted Pressure (G30/G31):
NOTE: Conversion kit: From Natural Gas to L.P. Gas - Europe: Whirlpool Part No. W10571757.
Conversion kit: From Natural Gas to L.P. Gas - Australia: Whirlpool Part No. W10571729.
Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10181947.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan 49022, U.S.A.
Manufacturing Site: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH, 43302, U.S.A.
EU Representatives: Whirlpool EMEA S.p.A., Via Carlo Pisacane, 1, 20016 Pero (MI) Italy
TECHNICAL SPECIFICATIONS – GAS DRYER
0.562703 m
Not Applicable
Not Applicable
DE, LU, PL
I
2E
0.562703 m
20 mbar
7.4 mbar
AU, NZ
minimum 1.13 kPa
0.74 kPa
21.1 MJ/h
AU, NZ
2.75 kPa
2.75 kPa
23 MJ/h
NL
I
2L
/hr
3
25 mbar
7.4 mbar
/hr
3
II
2L3B/P
0.562703 m
/hr
3
25 mbar
7.4 mbar
30 mbar
Not Applicable
29