protective tools and clothing required under the safety regulations or laws in effect in
the country where it is installed is recommended. In any case, always use appropriate
equipment and clothing, such as: safety shoes, protective gloves, a level.
For installation, please proceed as follows:
carefully inspect the installation area, removing any danger(s) to the operator:
Do not position the cabinet:
in environments with the presence of explosive gaseous substances;
outdoors and therefore where there are atmospheric agents;
near heat sources (in direct sunlight, near heating systems, incandescent lights,
etc.)
near air currents (near doors, windows, air-conditioning/heating systems, etc.)
exceeding speeds of 0.2 m/sec.
Remove the wooden supports on the bottom (used for transportation) and attach the
adjustable feet (Rif. 5) positioning them so that the unit is horizontal, using a level (Rif.
6) to check the alignment.
Before connecting the unit to the electricity, ensure that the plate data corresponds to
the characteristics of the electrical system to which it is to be connected.
For the unit to function properly, the temperature and relative humidity must not exceed
the limits for climate class 3 (+25°C; R.H.
regulations, under which the unit was tested.
Do not move the unit by pulling or pushing on the glass surfaces. Only use
the part underneath (Rif. 11).
If the unit is moved, repeat the levelling process, as improper levelling
could compromise the unit's operations.
11.Electrical connection - specialised technician -
BEFORE STARTING ANY OPERATION, FIRST DISCONNECT THE SYSTEM FROM
THE POWER SUPPLY!
The systems must be completed in accordance with the regulations that
govern construction, installation, use, and maintenance as envisaged under
the norms in effect in the country where the unit is installed.
ARNEG Spa declines any responsibility with regards to the user and third-
parties for damages caused by breakdowns or malfunctioning of the systems
installed upstream to the unit and for damages caused by the same due to
causes directly attributable to malfunctioning of the electrical system.
The unit must be protected upstream by an automatic omnipolar
thermomagnetic switch with appropriate characteristics. This must also act as
a general line disconnection switch.
Establishment of the electrical power supply line to the point of where it connects to the
unit is the responsibility of the Client. The dimensions of the electrical energy power
supply line must be determined in accordance with the electrical power used by the
unit (see Technical Specifications).
The unit comes with a connection ready for a plug (NOT SUPPLIED). Attach a plug
of suitable capacity for the electrical connection, onto the power lead in compliance
with safety rules: yellow-green = earth sky blue = neutral brown =live and conform
to the national regulations in effect
Remove any metal objects worn: rings, watches, bracelets, earrings, etc.
Check the electrical diagrams before carrying out the connection
Check that the voltage supply is as specified on the plate data.
Tell the operator where the switch is so that it can be reached quickly in an
EMERGENCY.
To guarantee correct operation, the maximum voltage variation must be between +/
- 6% of the nominal value.
Check that the power line has appropriate section cables, is protected against
00 30/01/2012
60%) as established in
The electrical system must be earthed!
Kiruna
EN-ISO 23953 - 2