④
Bracket
Pillar nut
Leave
5 mm
bracket and pillar nut
⑥
Screw the coupling nut
onto the valve stem until
the pillar edges rest on the
bracket
⑧
Lock the coupling nut
⑩
Drive the coupling up or down, until the
edges of the pillars rest on the bracket
⑪
Tighten the pillar nuts
6
⑤
appr. 5 mm
Move the coupling down until it hits the valve stem.
gap between
⑦
Repeat
12 mm (M8 to M12) resp. 16 mm (M14 and larger)
⑨
Tighten the clamping screws crosswise with 8 Nm
or
In case of any question, please do not hesitate to contact us:
Pillar end
Bracket
Continue moving until there is a 5 mm gap
between the pillar end and the bracket
⑤
+
⑥
⑤
⑥
and
until the valve stem is screwed
into the coupling nut by
8 Nm
WRONG
Phone: +49 (0) 6322 / 6003 ‐ 0
Mail: info@ps‐automation.com
appr. 5 mm
12 mm (M8, M12) /
16 mm (> M14)