4. Installation

After connecting to a supply voltage, the device is in sleep mode and must be started.
This process is accompanied by a short audio signal, which provides additional
feedback.
If the device is in standby, it is started via the standby button. After starting the device,
the last program used is loaded. The setup can be skipped by pressing the "Enter / Go
on" button twice (three times for the "Free" program).
The device is switched off correctly by holding the standby button.

5. Setup

The settings for the counting process are made in the setup phase of the program. In this
phase, depending on the counting program, either the stepwidth or the countstop and
exclusive counting keys are set.

5.1 Level 1: Select and confirm the program

The program is selected using the „Right/+" or „Left/-/Eval" buttons.
Now the last used program setting is loaded. By pressing any counting key the rest of the
setup phase can be skipped and the last count is displayed (option only in level 1).
Confirm the selection by pressing the key „Enter/Go On". The display now changes to
level 2 of the setup.

5.2 Level 2: Select and confirm stepwidth and countstop

a. Program „Reti"
When selecting the program Reti in level 1, the step size for the key "Div/Ery" is to
be selected in level 2. By pressing the "Right/+" key, the next higher value from the
series 1, 5, 10, 20, 30, 40, 50 is selected. As soon as the value reaches 50, further
inputs on this key will be ignored.
The next lower value is selected with the key "Left/-/Eval". Any further entry for this
key is ignored when the value reaches 1.
Confirm your selection by pressing the key „Enter/Go On".
Paul Marienfeld GmbH & Co. KG
Am Wöllerspfad 4
97922 Lauda-Königshofen, Germany
Tax number: 8028008501
VAT reg. no.: DE 811 479 105
Phone: +49 (0) 9343 6272-0
Deutsche Bank Würzburg
Fax: +49 (0) 9343 6272-25
IBAN: DE95 7907 0016 0130 0888 00
info@marienfeld-superior.com
SWIFT: DEUT DE MM 790
www.marienfeld-superior.com
Commercial Register Mannheim HRA 550306, personally liable
partner: Marienfeld-Verwaltungs-GmbH, 97922 Lauda-Königshofen
Commercial Register Mannheim HRB 560548, Managing Directors:
Gerd Marienfeld, Harry Marienfeld
18

Publicidad

Tabla de contenido
loading

Productos relacionados para Marienfeld Cellcounter

Este manual también es adecuado para:

7170006

Tabla de contenido