Installation; Installing/Replacing The Lamp; Danger To Life - Futurelight PHS-250 Pro-Head-Spot Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION

Installing/Replacing the lamp

For the installation, you need one MSD/HSD 200 GY-9.5, MSD/HSD 250 GY-9.5 or MSD 250/2 GY-9.5
lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
26
(8) Mode/Enter-button
(9) Down-button
(10) Up-button
(11) Display
(12) DMX-Out socket
(13) DMX-In socket
(14) Power supply
(15) Fuseholder
(16) Ventilation fan