17. Press [EXIT/DN] to exit. now you have edit and saved 15 (maximum) scenes through the controller, and
this type saved scenes can be saved by "CONT", and can be run when you enter to "RUN"
Save the scenes you edit to the "RUN"
5. Press [ENTER] for 3 seconds to enter main menu;
6. Select "CONT" by pressing [UP] button;
7. Press [ENTER], the display shows "CN-X", " X" stands for the total amount of steps you want to save to
"RUN", value "1-F", so you totally can save 15 scenes to the "RUN". For example if the "X" is 5, it means in
the "RUN", will run the first 5 scenes you saved in "EDIT";
8. Press [ENTER] TO save and exit, you will find in the "RUN", you edited scenes will run as per you set time.

Error Messages

When you turn on the fixture, it will make a reset first. The display may show "Xerr" while there are
problems with one or more channels. "X" stands for channel 1, 2, 4, 5, 6, 7, 8 equipped with a testing
sensor for positioning.
For example, when the display shows "4Err", it means there is some error in channel 4. If there are
some errors on channel 1, channel 2, channel 4 at the same time, you may see the error message
"1Err", "2Err","4Err" flash repeatly for 5 times, and then the fixture will generate a reset signal, all the
stepper motors will reset. If the error messages maintain after performing reset more than 3 times, it
will detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors (including
3 errors), all the channels can not work properly; but if the fixture has less than 3 errors, only the
channels which have errors can not work properly, others can work as usual.
1Err:
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke's magnetic-
indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its
driving IC on the main PCB). The yoke is not located in the default position after the reset.
2Err:
(TILT-head movement error) This message will appear after the reset of the fixture if the head's magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driving IC on the main PCB). The head is not located in the default position after the reset.
4Err:
(Color-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color wheel is not located in the default position after the reset.
5Err:
(Fix Gobo-wheel error) This message will appear after the reset of the ficture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The fix gobo wheel is not located in the default position after the reset.
6Err:
(Rotating gobo-wheel error ) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunctions(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main PCB). The rotating gobo-wheel is not located in the default position after the reset.
7Err:
(Rotating gobo indexing error) This message will appear after the reset of the fixture and if the magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver
circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
8Err:
(Prism-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The rotating gobo is not located in the default position after the reset.