1. OVERVIEW
The Steinberg Systems series of electronic price scales are equipped with
high precision load cell as primary instrument, the secondary instrument de-
signed by using new technology and new materials such as 8951 single-chip
microprocessor as main chip and A/D converted with triple-integral.
The Steinberg Systems series of electronic price scale are good products with
reasonable prices. It has the functions of accumulation up to 99 times, over-
load and under-voltage alarms, auto and continuous AC/DC shift, power sup-
ply identification, auto temperature compensation, auto power-saving mode
without weights for 20 seconds and unit price storage and shift (8 different
prices can be saved for scale with 24 keys). Particularly, it can protect the
saved data to ensure accurate weighing.
2. FEATURES & SPECIFICATIONS
Model
3110 SBS-PW-60/5
Class
Precision
Rated capacity
60 kg
Resolution (Standard)
6000
Standard division (e)
5g
EN
Max capacity
60kg
Min capacity
Zero range
Tare range
0~60kg
Zero tracking range
Limit display
60.090kg
NOTE: e=d
2.3 ERROR RANGE
Weight
Error range
(described as e)
Outgoing inspection
0≤m≤500e
±0.5e
500e<m≤2000e
±1.0e
2000e<m≤3000e
±1.5e

3. ELECTRICAL CHARACTERISTICS

3.1 Working voltage: 230V(+10%~-15%); 50±2%Hz / 110V(+10%~-
15%); 60±2%Hz
Power consumption:
Not larger than 1VA, normal power consumption lower than 0.2VA
3111 SBS-PW-100/10
III
1/3000 F.S.
100 kg
10000
10g
100kg
200g
0~60d
0~100kg
0~5g
100.090kg
Inspection after repair
±1.0e
±2.0e
±3.0e
20
3.2 Direct current characteristics
Storage battery capacity: 6V 4Ah
Rated voltage: DC6V
4. DISPLAY CHARACTERISTICS
4.1 Display windows
Weight window: 5 digits
Unit price window: 5 digits
Total amount window: 6 digits
WEIGHT (kg)
SBS-PW-60/5
CLR
Clearing the unit price.
ZERO
The ZERO key zeroes the scale.
TARE
The TARE key subtracts tare values and changes the scale from gross
mode (no tare) to net mode.
ADD
Adding mode.
SAVE
Saving unit prices.
M1-M7 The M keys are used to store data (unit price value at 8 different
locations) in your scale.
0~9
The NUMERIC key (0~9) is used for setting unit price data.
DECIMAL POINT key is used for set the decimal position of unit price.
FUN
Backlight display switching on or off.