Battery Replacement - SATA adam 2 Serie Instrucciones De Servicio

Ocultar thumbs Ver también para adam 2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 88
Operating instructions pressure measuring devices SATA adam 2, SATA adam 2 U
Information!
• Further cleaning tips can be found at www.sata.com/TV.
9.

Battery Replacement [5]

• Replace the battery outside of explosive areas only!
• Please observe safety instructions in chapter 6.4!
Only RENATA batteries (CR2032) must be used. Use the battery kit (Art.
No. 160739) consisting of battery, O-rings, locking clip, elastic rubber
strap and special tool. According to the intensity of use, the battery will
last between 1 to 3 years. The battery capacity is electronically controlled.
o e clude measurement errors the dis la s itches off ith insufficient
battery power. In this case, the battery has to be replaced.
Depending on display and use, the battery must be replaced within the
following time frames:
Display:
Battery symbol
E clamation oints flashing
Display "Lo
" upon switching-on
b
1. Disassembly of the display [5-1] (also see chapter 7.1).
2. Open display using the special tool and the elastic rubber strap
{FORCED_LINE_BREAK}
[5-2], [5-3].
3. Remove the battery with special tool [5-4].
4. Insert a new RENATA CR 2032 (observe polarity of battery!).
5. Remove the sealing with the special tool [5-5] and insert the new
sealing.
6. Screw the housing back onto the display. To prevent penetration of
cleaning agent, please ensure to tighten the housing hermetically
(completely) [5-3].
7. If required, replace the locking clip and the small O-ring. Flat side of
locking clip must be visible [no illustration].
Danger! Risk of explosion!
4-5 weeks
<1 week
eeks
US
309

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Adam 2 miniAdam 2 displayAdam 2 u

Tabla de contenido